/ Коммутаторы Ruijie / RG-N18000

RG-N18000

Коммутаторы ядра или агрегации RG-N18000 series

image-main

image-1

image-2

image-3

Описание

Ruijie Newton 18000 Switch Series (RG-N18000) is industry leading core switch with a broad spectrum of specialized campus network features. Ruijie RG-N18000 core switches achieve virtualization, and wired wireless integration. With AC line card, it supports management of maximum 2560 APs. At the same time, Ruijie RG-N18000 core switches support combo-port line module option, giving you a variety of options for your network.

Ruijie brings you an innovative “Network Cloud Mode” featuring strong cloud and light access: Building a strong core (unified gateway, authentication, multiservice) for light access.

Ruijie RG-N18000 Series deploys an advanced software architecture design and is one of the world’s leading core switches with the highest specifications. The series supports CLOS switching architecture and offers sustaining bandwidth upgrade and service support capacities.

RG-N18000 Series has 4 models :RG-N18014 , RG-N18012 , RG-N18010 and RG-18007 to meet various port density and performance requirements. The switches deliver excellent investment protection and are suitable for deployment in a wide range of settings such as data center, MAN, campus network or integrated network of campus network.

 

Параметры

Model

RG-N18007

RG-N18010

RG-N18012

RG-N18014

Module Slots

7 (2 for control engines)

10(2 for control engines)

12(2 for control engines)

14 (2 for control engines)

Modular Power Slots

6 (4 for system power; 2 for PoE power)

10 (8 for system power; 2 for PoE power)

6 (all for system power)

8 (all for system power)

Fan Slots

1

4

2

5

Control Engine Slots

2

2

2

2

Service Module Slots

5

8

10

12

Fabric Engine Slots

N/A

4

4

4

Switching Capacity

50Tbps/208.5Tbps

80Tbps/333.6Tbps

100Tbps/417Tbps

120Tbps/500.4Tbps

Packet Forwarding Rate

900Mpps

11,520Mpps

3,840Mpps

17,280Mpps

Max. Number of 10GE Ports

Up to 240

Up to 768

Up to 480

Up to 1,152

Max. Number of 40GE Ports

Up to 60

Up to 192

Up to 120

Up to 288

Max. Number of 100GE Ports

N/A

Up to 96

Up to 120

Up to 144

PoE

Support

Support

N/A

N/A

Port Buffer

Up to 16MB

Up to 24GB

Up to 24MB

Up to 24GB

ARP Table

Up to 170K

MAC Address

Up to 512K

Up to 512K

Up to 225K

Up to 512K

Routing Entries

Up to 384K

Routing Table Size
(IPv4/IPv6)

Up to 12K/6K

Up to 384K/128K

Up to 384K/128K

Up to 384K/128K

Multicast Entries
(IPv4/IPv6)

Up to 16K/8K

ACL Entries

Up to 8K

VLAN

4K

QinQ

Basic QinQ, Flexible QinQ

Link Aggregation

AP, LACP

Port Mirroring

Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN

Spanning Tree Protocols

STP, RSTP and MSTP

DHCP

Support DHCP relay, DHCP snooping, DHCP server, DHCP client

Multiple Spanning Tree (MST) Instances

64 (not include default 0)

Maximum Aggregation Port (AP)

Up to 256

Virtual Routing and Forwarding (VRF) Instances

Up to 2K

Data Center Unified Network Features

L2 GRE

VXLAN

VXLAN Layer 2 Bridge, VXLAN Layer 3 Bridge, EVPN VXLAN

SDN

OpenFlow

VSU (Virtual Switch Unit)

Up to 2 stack members

VSD (Virtual Switch Device)

Up to 12 VSD units

L2 Features

Jumbo Frame, 802.1Q, STP, RSTP, MSTP, Port-based VLAN, Super VLAN, Private VLAN, Protocol-based VLAN, IP subnet-based VLAN, Guest VLAN, GVRP, QinQ, Flexible QinQ, LLDP, ERPS (G.8032)

Tip: Guest VLAN features are only supported by specific software versions

Layer 2 Protocols 

IEEE802.1d (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, Jumbo Frame (9Kbytes), IEEE802.1ad (QinQ and flexible QinQ), GVRP

Layer 3 Features

ARP, IPv4/v6, PBR v4/v6

Layer 3 Protocols (IPv4) 

Ping, Traceroute, Equal-Cost Multi-Path Routing (ECMP), URPF, GRE Tunnel(4 over 6), GRE Tunnel(6 over 4), IPv4 VRF

Centralized Authentication (With RG-SAM+ Integration)

60K IPv4 and IPv6 dual-stack concurrent users; 1,000 devices per second authentication speed; Authentication modes including 802.1x/ Portal/Mac/IPoE; Portal authentication, RADIUS and TACACS+ user authentication; Layer 2 portal, Layer 3 portal authentication; Traffic billing, traffic control, refined management; Gateway authentication

IPv4 Features

Static routing, RIP, OSPF, IS-IS, BGP4, VRRP, Equal-cost routing, Policy-based routing, GRE tunnel

IPv6 Features

Static routing OSPFv3, BGP4+, IS-ISv6, MLDv1/v2, VRRPv3, Equal-cost routing, Policy-based routing, Manual tunnel, Auto tunnel, ISATAP tunnel, GRE tunnel

Basic IPv6 Protocols

DHCP Relay v6, DHCP Server v6, Telnet v6, TFTP Client v6, FTP v6, NTP client v6, NTP server v6

IPv6 Routing Protocols

RIP, RIPng, OSPFv2/v3, BGP4, BGP4+, IS-ISv4/v6, Routing Policy

IPv6 Tunnel Features

6over4 Manual Tunnel, 6to4 Auto Tunnel, Manual Tunnel, Auto Tunnel, ISATAP Tunnel, IPv4 over IPv6 Tunnel, IPv6 over IPv6 Tunnel, GRE Tunnel(4 over 6), GRE Tunnel(6 over 6)

Multicast

IGMP v1/v2/v3, IGMP proxy, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD, Multicast static routing

MPLS

MPLS forwarding, MPLS VPN, VPLS/VPWS , LDP, LSP

G.8032

Support

ACE Capacity

Up to 8K

ACL

Standard/Extended/Expert ACL; ACL 80; IPv6 ACL

QoS

802.1p, Queue scheduling mechanisms (SP, WRR, DRR, WFQ, SP+WFQ, SP+WRR, SP+DRR, and 8 hardware queues at egress ports), RED/WRED, Input/output port-based speed limit

IPv6 ACL

Support

Reliability

Control engine 1+1 redundancy; power supply 1+1 redundancy; Hot-swappable components; Hot patch and online patch upgrade; GR for OSPF/IS-IS/BGP; BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing

EEE Format

Support EEE (802.3az)

Security

NFPP (Network Foundation Protection Policy), CPP (CPU Protection), DAI, ARP Check, Port Security, IP Source Guard, 802.1x, Portal authentication, RADIUS and TACACS+ user login authentication, uRPF, Account privileges and password security policy, Unknown multicasts are not delivered to CPU and support unknown unicasts suppression, Support SSHv2 to provide a secure and encrypted channel for user login

Manageability

Console/AUX Modem/Telnet/SSH2.0 command line configuration; FTP, TFTP, Xmodem file upload/download management; SNMP V1/V2c/V3; RMON; NTP clock; Fault alarm and self-recovery; System log; sFlow

Hot Patch

Support

CWMP

Support

Smart Temperature Control

Fan speed auto-adjustment; Fan malfunction alerts; Fan status check

Smart Power Supply

Support power control and management

Other Protocols

DHCP client, DHCP relay, DHCP server, ARP proxy, Syslog

Dimensions
(W x D x H) (mm)

442 x 598 x 352.8

442 x 836 x 797.3

442 x 725 x 708.4

442 x 814 x 886.2

Rack Height

8RU

18RU

16U

20RU

Weight

30.2kg
(total weight of empty chassis and fans)

103.32kg
(total weight of empty chassis and fans)

105kg(total weight of empty chassis and fans)

107.55kg
(total weight of empty chassis and fans)

MTBF

229K hours

259K hours

259K hours

216K hours

Power Supply

RG-PA1600I: 90-180V~ 1200W; 180-264V~ 1600W

RG-PA600I: 90-180V~ 600W; 180-264V~ 600W

RG-PD1600I: -40.5VDC-75VDC ~1600W

RG-PD600I: -40.5VDC-75VDC ~600W

RG-PA1600I-PL: 90-180V~1000W; 180-264V~1600W

RG-PA3000I-PL: 90-180V~ 1200W; 210-264V~ 3000W

RG-PA1600I: 90-180V~ 1200W; 180-264V~ 1600W, 16A

RG-PA600I: 90-180V~ 600W; 180-264V~ 600W, 10A

RG-PD1600I: -40.5VDC-75VDC ~1400W

RG-PD600I: -40.5VDC-75VDC ~600W

RG-PA1600I-PL: 90-180V~1000W;

180-264V~1600W (PoE)

RG-PA3000I-PL:  90-180 V~1200W;

210-264V~3000W (PoE)

RG-PA1600I: 90-180V~1200W; 180-264V~ 1600W; 16A

RG-PA600I: 90-180V~ 600W; 180-264V~ 600W; 10A

RG-PD1600I: -40.5VDC-75VDC ~1400W

RG-PD600I: -40.5VDC-75VDC ~600W

RG-PA1600I: 90-180V~ 1200W; 180-264V~ 1600W, 16A

RG-PA600I: 90-180V~ 600W; 180-264V~ 600W, 10A

RG-PD1600I: -40.5VDC-75VDC ~1400W

RG-PD600I: -40.5VDC-75VDC ~600W

Power Consumption 

<432W

<730W

<518W

<860W

PoE Power

<6,000W

<6,000W

N/A

N/A

Temperature

Operating temperature: 0ºC to 50ºC

Storage temperature: -40ºC to 70ºC

Humidity

Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH

Operating Altitude

-500m to 4,000m


 

Weight and Typical Power

Below table lists the weight and maximum power consumption of the Newton 18000 switch platform.

Component

Weight

Maximum Power

Main Chassis

  • Ruijie RG-N18007 chassis with fan

30.2kg

432W

  • Ruijie RG-N18010 chassis with fan

103.32kg

730W

  • Ruijie RG-N18012 chassis with fan

105kg

518W

  • Ruijie RG-N18014 chassis with fan

107.55kg

860W

Control Engine

1.68 kg

40W

  • M18007-CM II

2.0kg

102W

  • M18007-CM II Lite

2.0kg

102W

  • M18010-CM

1.68kg

40W

  • M18010-CM II

2.04kg

95W

  • M18012-CM

1.68kg

40W

  • M18012-CM II

2.0kg

95W

  • M18014-CM

3.22kg

40W

  • M18014-CM II

3.58kg

100W

Fabric Engine

  • M18010-FE-C I

2.72kg

90W

  • M18010-FE-D I

2.8kg

107W

  • M18010-FE-D III

3.36kg

313W

  • M18012-FE-D I

2.2kg

107W

  • M18014-FE-D I

3.76kg

158W

  • M18014-FE-D III

4.56kg

425W

Power Supply

  • RG-PA1600I

2.04kg

N/A

  • RG-PA600I

1.64kg

  • RG-PA1600I-P

1.6kg

1.6kg

  • RG-PA3000I-PL

1.6kg

  • RG-PD1600I

1.6kg

  • RG-PD600I

1.3kg

Line Card & Service Module

  • M18000-44SFP4XS-ED

3.76kg

135W

  • M18000-44SFP4XS-EF

3.86kg

175W

  • M18000-44SFP4XS-CB

5.06kg

267W

  • M18000-48GT-ED

3.7kg

95W

  • M18000-48GT-EF

3.8kg

175W

  • M18000-48GT-P-ED

4.04kg

95W

  • M18000-24GT20SFP4XS-ED

3.76kg

100W

  • M18000-08XS-ED

3.42kg

85W

  • M18000-08XS-EF

3.52kg

120W

  • M18000-16XS-CB

4.20kg

156W

  • M18000-16XT-CB

4.50kg

250W

  • M18000-40XS-CB

5.20kg

296W

  • M18000-48XS-DC

4.25kg

232W

  • M18000-24XS4QXS-DC

4.0kg

208W

  • M18000-12QXS-DC

3.92kg

200W

  • M18000-24QXS-DB

4.95kg

374W

  • M18000-12CQ-EH

5.4kg

366W

Multiservice Module

  • M18000-MSC-ED

4.58kg

190W

  • M18000-WS-ED

4.58kg

190W

  • RG-WALL 1600-B-ED

4.58kg

190W

Информация для заказа

1. Main Chassis & Engine Management
Select the main chassis and control engine according to specific product model.

Model

Description

RG-N18000 Series Main Chassis & Control Engine

RG-N18014

14-slot Chassis with fan (without power supply)

RG-N18012

12-slot Chassis with fan (without power supply)

RG-N18010

10-slot Chassis with fan (without power supply)

RG-N18007

7-slot Chassis with fan (without power supply)

M18014-CM II

N18014 2nd Generation Control Engine

M18014-CM

N18014 Control Engine

M18012-CM II

N18012 2nd Generation Control Engine

M18012-CM

N18012 Control Engine

M18010-CM II

N18010 2nd Generation Control Engine

M18010-CM

N18010 Control Engine

M18007-CM

N18007 1st Generation Control Engine

M18007-CM II

N18007 2nd Generation Control Engine

M18007-CM II Lite

N18007 2nd Generation Lite Control Engine

 

2. Power Supply
Please select at least 1 power module or up to N+M redundancy according to the power supply requirement of the device.

Model

Description

RG-PA600I

N18000 Power Module (support redundancy, AC, 600W, 10A)

RG-PD600I

N18000 Power Module (support redundancy, DC, 600W)

RG-PA1600I

N18000 Power Module (support redundancy, AC, 1600W, 16A)

RG-PD1600I

N18000 Power Module (support redundancy, DC, 1400W)

RG-PA1600I-PL

N18000 PoE Power Module (support redundancy, AC, 1600W, 16A)

RG-PA3000I-PL

N18000 PoE Power Module (support redundancy, AC, 3000W, 16A)

 

3. Fabric Engine
Please select at least 1 or up to 4 fabric engines. It is recommended to select at least 2 to ensure fabric engine redundancy.

Model

Description

M18014-FE-D III

N18014 D Series 3rd Generation Fabric Engine (For ED and DB series Line Card and Service Module)

M18014-FE-D I

N18014 D Series 1st Generation Fabric Engine (For ED and DB series Line Card and Service Module)

M18012-FE-D I

N18012 D Series 1st Generation Fabric Engine

M18010-FE-D III

N18010 D Series 3rd Generation Fabric Engine (For ED and DB series Line Card and Service Module)

M18010-FE-D I

N18010 D Series 1st Generation Fabric Engine (For ED and DB series Line Card and Service Module)

M18010-FE-C I

N18010 C Series 1st Generation Fabric Engine (For CB series Line Card and Service Module)


4. Line Card & Service Module
Select the host line cards according to your application scenario.

Model

Description

M18000-44SFP4XS-ED

44 Gigabit Ethernet fiber ports (SFP, LC), 4-port 10GE Ethernet optical interface board (SFP+, LC)

M18000-44SFP4XS-EF

44 Gigabit Ethernet fiber ports (SFP, LC), 4-port 10GE Ethernet optical interface board (SFP+, LC)

M18000-48GT-ED

48-port Gigabit Ethernet electrical interface board (RJ45)

M18000-48GT-EF

48-port Gigabit Ethernet electrical interface board (RJ45)

M18000-48GT-P-ED

48-port Gigabit PoE Ethernet electrical interface board (RJ45)

M18000-24GT20SFP4XS-ED

24-port Gigabit Ethernet electrical interface board (RJ45), 20 Gigabit Ethernet fiber ports (SFP, LC), 4 10GE Ethernet fiber ports (SFP+, LC)

M18000-08XS-ED

8 10GE fiber ports (SFP+, LC)

M18000-08XS-EF

8 10GE fiber ports (SFP+, LC)

M18000-16XT-CB

16 10GE copper ports (RJ45)

M18000-48XS-DC

48 10GE fiber ports (SFP+, LC)

M18000-24XS4QXS-DC

24 10GE fiber ports (SFP+, LC) + 4-port 40GE optical interface module (QSFP+, MPO)

M18000-12QXS-DC

12 40GE fiber ports (QSFP+, MPO)

M18000-24QXS-DB

24 40GE fiber ports (QSFP+, MPO)

M18000-12CQ-EH

12 100GE fiber ports(QSFP28)

Multi-service Line Card

RG-WALL 1600-B-ED

Firewall card, 2 10GE fiber ports (SFP+, LC)

M18000-MSC-ED

Service module with Gateway authentication and accounting function, integrated with high-level core switches RG-N18000 series, to support authentication, throughput based accounting, URL audit and flow control function.

M18000-WS-ED

WS Series Wireless Controller Module for RG-N18000 Switch Series, 2 1G/10GBASE-X SFP+ ports, 128 APs License by default, maximum 2560 APs or 4000 Wall APs License

 

5. Transceiver and Cable

Model

Description

Mini-GBIC-SX-MM850

1000BASE-SX mini GBIC Transceiver (850nm)

Mini-GBIC-LX-SM1310

1000BASE-LX mini GBIC Transceiver (1310nm)

Mini-GBIC-GT

1000BASE-TX, SFP Transceiver (100m)

Mini-GBIC-LH40-SM1310

1000BASE-LH mini GBIC Transceiver, SM (1310nm, 40km)

Mini-GBIC-ZX50-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 50km)

Mini-GBIC-ZX80-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 80km)

Mini-GBIC-ZX100-SM1550

1000BASE-ZX mini GBIC Transceiver (1550nm, 100km)

XG-SFP-AOC1M

10GBASE SFP+ Optical Stack Cable (included both side transceivers) , 1 Meter

XG-SFP-AOC3M

10GBASE SFP+ Optical Stack Cable (included both side transceivers), 3 Meter

XG-SFP-AOC5M

10GBASE SFP+ Optical Stack Cable (included both side transceivers), 5 Meter

XG-SFP-AOC10M

10GBASE SFP+ Optical Stack Cable (included both side transceivers), 10 Meter

XG-SFP-SR-MM850

10GBASE-SR, SFP+ Transceiver, MM (850nm, 300m, LC)

XG-SFP-LR-SM1310

10GBASE-LR, SFP+ Transceiver, SM (1310nm, 10km, LC)

XG-SFP-ER-SM1550

10GBASE-ER, SFP+ Transceiver, SM (1550nm, 40km, LC)

XG-SFP-ZR-SM1550

10GBASE-LC, SFP+ Transceiver, SM (1550nm, 80km, LC)

40G-AOC-5M

40G Cable for QSFP+, 5M

40G-QSFP-SR-MM850

40GBASE-SR, QSFP+ Transceiver, MM (850nm, 100m with OM3 fiber, 150m with OM4 fiber, MPO)

40G-QSFP-LSR-MM850

40GBASE-SR, QSFP+ Transceiver, MM (850nm, 300m with OM4 fiber, 400m with OM4 fiber, MPO)

40G-QSFP-LR4-SM1310

40G LR Single-mode Fiber Module, QSFP+ Transceiver, LC, 10km (1310nm)

40G-QSFP-LR4-PSM-SM1310

40G LR Single-mode 1-to-4 Fiber Module, QSFP+ Transceiver, LC, 10km (1310nm)

QSFP-MPO8-4LC-SM-1M

40G Single-mode 1-to-4 Fiber Jumper, MPO/APC-4*LC/PC, 8 cores, 1m, for 40G-QSFP-LR4-PSM-SM1310

QSFP-MPO8-4LC-MM-1M

40G Single-mode 1-to-4 Fiber Jumper, MPO/APC-4*LC/PC, 8 cores, 1m, for 40G-QSFP-SR-MM850 and 40G-QSFP-LSR-MM850

100G-QSFP-LR4-SM1310

100G LR Fiber Module, QSFP28 Transceiver, LC, 10km (1310nm)

FE-SFP-LX-MM1310

100BASE-LX, SFP Transceiver, MM (1310nm, 2km, LC).

FE-SFP-LH15-SM1310

100BASE-LH, SFP Transceiver, SM (1310nm, 15km, LC).

GE-SFP-LX20-SM1310-BIDI

1000BASE-LX, SFP Transceiver, BIDI-TX1310/RX1550, 20km, LC

GE-SFP-LX20-SM1550-BIDI

1000BASE-LX, SFP Transceiver, BIDI-TX1550/RX1310, 20km, LC

GE-SFP-LH40-SM1310-BIDI

1000BASE-LH, SFP Transceiver, BIDI-TX1310/RX1550, 40km, LC

GE-SFP-LH40-SM1550-BIDI

1000BASE-LH, SFP Transceiver, BIDI-TX1550/RX1310, 40km, LC

CON-DB9/RJ45-2M

Ruijie Console Cable RJ45-to-DB9 (2m)

Документация

RG-N18000 Switch Series Datasheet